DY-300W-24-S

DY-300W-24-S


· Design for indoor installation · Protections:Short circuit/Overload/Over voltage · Forced air cooling by built-in DC ball bearing fan · 100% full load burn-in test · Suitable for LED lighting · Products passed CE, RoHS certification · 3 years warranty

Product Category:

  • Product Description
  • Model DY-300W-12-S DY-300W-24-S
    OUTPUT DC voltage 12V±5% 24V±5%
    Rated current 25A 12.25A
    Current range 0-25A 0-12.25A
    DC output power 300W 300W
    Ripple &Noise (max) note.2 380mVp-p 460mVp-p
    Load stability ±5% ±5%
    Voltage tolerance  note.3 ±0.5% ±0.5%
    Setup, Rise time   note.4 200ms,50ms 200ms,50ms
     Hold up time(Typ.) 20ms 20ms
    INPUT Voltage range 90-150VAC  or  170-260VAC
    Frequency range 50-60Hz
    AC current(Typ.) 2.6A/110VAC   1.7A/260VAC
    Inrush current Cold start ≤40A
    Incoming line stability ±5%
    Power factor(Typ.) PF≧0.5
    Efficiency  (Typ.) ≥80% ≥85%
    Leakage current ≤5mA/260VAC
    PROTECTION Short circuit   The power supply can resume normal operation when the short circuit is removed during power supply.
    Overload 105%-200% rated output power
    Protection type:Hiccup mode,recovers automatically after fault condition is removed
    Over current After the over current fault is removed, the power supply will automatically resume normal operation.
    Over voltage   When the output voltage exceeds the rated voltage, the power supply will be protected and normal operation can be resumed after the fault is removed.
    ENVIRONMEN Working temp.    -25℃ to 40℃,Full load, Normal operation
    Working humidity 5%(0℃)~90%(40℃)RH,72Hrs,Full load, Normal operating
    Storage temp., humidity -30℃ to 80℃
    Temp. coefficient ±0.03%℃(0-5℃)
    Vibration 5~9Hz,A=1.5mm. / 9~200Hz,Acceleration 5m/S2
    SAFETY&EMC Aging test Input voltage : 220V 50HZ   Rated output current 25℃,  Burn-in 2h
    Withstand voltage Input and output: 3KVAC 5mA 3s input and shell; 1.5KVAC 5mA 3s
    Isolating resistance Between input and output, input and shell: 500VDC / 10MΩ
    EMC emission Compliance to EN55032(CISPR32)Class B.EN61000-3-2,-3,EAC TP TC 020
    EMC immunity Compliance to EN61000-4-2.3.4.5.6.8.11.EN55024,light industry level,criteria A,EAC TP TC 020
    Safety standards  Design by IEC60950 standard
    NOTE All parameters NOT specially mentioned are measured at 240VAC input,rated load and 25℃ of ambient temperature.
    Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf &47uf parallel  capacitor.
    Tolerance: includes set up tolerance. Line regulation and load regulation.
    Length of set up time is measured at first cold start .Turning ON/OFF the power supply may lead to increase of the set up time.

     

     

    Others

    Dimension 223x68x40(mm)
    Carton quantity 50pcs/Carton
    Carton size 485x245x410(mm)