• undefined
undefined
+
undefined
+
  • undefined

DY-400W-12/24


• New appearanceo • Semi filled glue • Adjustable power • Safe low voltage, No touch hazard • Mute without interference • Efficiency > 90% min@230Vac full load • Product cooling way:Natural air cooling • Mean Time Between Failure (MTBF) ≥50000 hours • Protection types: Short circuit, Over load • Long life design warranty for 3 years • Applied in: Suitable for LED lighting,industrial control equipment, instruments, etc

Product Category:
  • Product Description
  • Features:
    • New appearanceo
    • Semi filled glue
    • Adjustable power
    • Safe low voltage, No touch hazard
    • Mute without interference
    • Efficiency > 90% min@230Vac full load
    • Product cooling way:Natural air cooling
    • Mean Time Between Failure (MTBF) ≥50000 hours
    • Protection types: Short circuit, Over load
    • Long life design warranty for 3 years
    • Applied in: Suitable for LED lighting,industrial control equipment, instruments, etc

     

     Model

    DY-400W-12-LX

    DY-400W-24-LX

    OUTPUT

    DC voltage

    12V

    24V

    Rated current

    16A

    10A

    Current range

    0-16A

    0-10A

    DC output power

    400W

    400W

    Ripple & Noise ( max) note.2

    800mvp-p

    800mvp-p

    Current Tolerance

    ±5%

    ±2%%

    Line Regulation

    ±2%

    ±1%

    Load Regulation

    ±2%

    ±1%

    Setup Time

    <800ms @230Vac full load

    Power Regulation

     

    100%

    75%

    50%

    35%

    ON-1

     

    ·

     

    ·

    ON-2

     

     

    ·

     

    INPUT

    Voltage range

    180-264VAC

    180-264VAC

    Frequency range

    47-63Hz

    47-63Hz

    Efficiency

    90%@220Vac full load

    Power Factor

    /

    Thd

    /

    Input Max Current

    2A @180Vac full load 180Vac input,full load lin 〈 1.7A

    Inrush Current

    Cold Start 130A max @230Vac Cold start the largest 130A@230Vac

    PROTECTION

    Short Circuit

    Hiccup Mode, recovers automatically after fault condition is removed

    Over load

    105%-130% rated output power

    Protection mode: the product starts to gradually reduce the output voltage untilthe hiccup state to protect the product from damage. When the fault is removed, the power supply returns to normal operation

    Over Temperature

    /

    ENVIRONMEN

    Working Temp.

    -25℃~ +55C( Refer to "derating curve”)

    Max Enclosure Temp.

    T case=+70 ℃

    Working Humidity

    20 ~ 90% RH Non-condensing

    Storage Temp,Humidity

    -40~ +85C,10 ~95% RH

    Vibration

    10~500Hz,5G 12Min./1cycle, period for 60min , each along X,Z,Y axes

    SAFETY& EMC

    Safety

    /

    Emc

    /

    Lightning Suger

    Differential Mode +/- 2.5KV(2ohm)

    Leakage Current

    <0.75mA /230Vac

    RELIABILITY

    The power supply shall under go a minimum of 2 Hours burn-in test at full load condition

    The MTBF shall be at least 100k hrs at 25°C, Full load and nominal input condition

    warranty for 3years

     

    1.1 Efficiency Vs Input voltage (DY-400W-12-LX )


    1.2 Static characteristic curve (DY-400W-12-LX )


    1.3 Typical Lifetime(DY-400W-12-LX )


    1.4 Efficiency vs Load (DY-400W-12-LX )

     

    XH-12V-400W                              

     

    Keywords:
    • LED POWER SUPPLY
    • DingYing