DY-400W-24-B

DY-400W-24-B


Features: • Design for indoor installation • Protections:Short circuit/Overload/Over voltage • Forced air cooling by built-in DC ball bearing fan • 100% full load burn-in test • Suitable for LED lighting • Products passed CE, RoHS certification • 3 years warranty

Product Category:
  • Product Description
  • Features:
    • Design for indoor installation
    • Protections:Short circuit/Overload/Over voltage
    • Forced air cooling by built-in DC ball bearing fan
    • 100% full load burn-in test
    • Suitable for LED lighting
    • Products passed CE, RoHS certification
    • 3 years warranty

     

    SPECIFECATION

    Model

    DY-400W-12-B

    DY-400W-24-B

     

     

     

    OUTPUT

    DC voltage

    12V±5%

    12V±5%

    Rated current

    33.3A

    16.6A

    Current range

    0-33.3A

    0-16.6A

    DC output power

    400W

    400W

    Ripple &Noise(max)note.2

    <350mV

    <350mV

    Load stability

    1%

    1%

    Voltage tolerance note.3

    ±5%

    ±5%

    Setup, Rise time note.4

    200MS,50MS

    200MS,50MS

    Hold up time(Typ.)

    20MS

    20MS

     

     

     

    INPUT

    Voltage range

    178-250VAC

    Frequency range

    50-60Hz

    AC current(Typ.)

    3.35A 230v

    Inrush current

    Cold start 40A

    Incoming line stability

    0.5%

    Power factor(Typ.)

    PF0.6

    Efficiency (Typ.)

    >88%

    >91.7%

    Leakage current

    5A/230VAC

     

    PROTECTION

    Short circuit

    The power supply can resume normal operation whenthe short circuit is removed during power supply.

    overload

    105%-200% rated output power

    Protection type:Hiccup mode,recovers automaticallyafter fault condition is removed

    over current

    After the over current fault is removed, the power supplywill automatically resume normal operation.

    over voltage

    when the output voltage exceeds the rated voltage, thepower supply will be protected and normal operationcan be resumed after the fault is removed.

     

     

    ENVIRONMEN

    Working temp.

    -10°℃~+50°C( Refer to "derating curve)

    Working humidity

    -20~+4520%~90%RH

    Storage temp., humidity

    -40°℃~8510%~95%RH

    Temp. coefficient

    0.03%°C(O-5C)

    Vibration

    10-500Hz,2G 10min./ 1 cycle,60 min. each axes

     

     

     

     

     

    SAFETY&EMC

    Aging test

    Input voltage : 220V 50HZ Rated output current 25,Burn-in 2hl

    Withstand voltage

    Input and output: AC2.5KV 5mA 6os input and shell;AC2KV 5mA 60S

    Isolating resistance

    Between input and output,input and shell: 500VDC /10OMQ

    EMC emission

    Compliance to EN55032(CISPR32)Class B.EN61000-3-2,-3,EAC TP TC 020

    EMC immunity

    Compliance to EN61000-4-2.3.4.5.6.8.11.EN55024,lightindustry level,criteria A,EAC TP TC 020

    Safety standards

    UL62368-1,TUV EN62368-1.EAC TP TCO04 approved

     

     

     

    NOTE

    All parameters NOT specially mentioned are measured at 230VAC input,rated loadand 25of ambient temperature.

    Ripple & noise are measured at 20MHz of bandwidth by using a 12twisted pair-wire terminated with a 0.1uf &47uf parallel capacitor.

    Tolerance: includes set up tolerance.Line regulation and load regulation.

    Length of set up time is measured at first cold start .Turning ON/OFF the powersupply may lead to increase of the set up time.

     

    DY-500W-24-BDY-500W-24-BDY-500W-24-B

    22

    Dimension 235×50×23(mm)
    Carton quantity 70pcs/Carton
    Carton size 470×340×185(mm)
    Net Weight 0.36kg/pcs
    Total Weight 22kg